CEILING MOUNTED DEHUMIDIFIER

  • Nominal dehumidification: 960L/day
  • Power supply: 380V/50Hz
  • Rated input power: 11KW
  • Rated input current: 16.8A
SKU: DJDD-9681E Category:

Features

  • High efficiency / energy saving / less power consumption
  • Automatic restart on and off with memory function
  • Continuously drainage in 24 hours by tube
  • High precision humidity control with ±3%RH,  ambient humidity controlled >RH45% based on temp
  • Compressor with 3 minutes delay – starting protection
  • Auot-defrosting function
  • High and Low pressure protection
  • Malfunction display Error code timely
  • Easy operation and simple installation on ceilin

Why DJDD-9681E

Industrial ducted dehumidifier is designed for some special application room, machine can be installed outside room, and connect to air inelt and air outlet by ducting pipe. It will be idea solution to save limited space in the application room.

Model numberDJDD-9681E
Nominal dehumidification(27℃,RH60%)960L/day
Power supply380V/50Hz
Rated input power11KW
Rated input current16.8A
Circulating air flow10000m³/h
Humidity control range40%-95%
Drainage wayHose connection
Working temperature
range
5~38°C
RefrigerantR407c/R410a
Noise≤70db
Compressor typeRotary
Warranty1 Year
Standard packagingWooden case
CertificationCE
Net weight/Gross weight300kg/390kg
Air inlet size1460×565 mm
Air outlet size1590×205 mm
Machine size1960x1200x700 mm
Package size2000x1265x840 mm

Working Principle

The principle of the dehumidifier is-to discharge theair vapor-cooled self-condensing liquid through daocooling,reduce the air humidity,and achieve thedehumidification effect. The working principle is topass the compressor dao,two devices (evaporator,condenser),capillary tube,and The refrigerant in thecopper pipe changes from a high-temperature andhigh-pressure gas to a low-temperature and low-pressure liquid.The air inhaled into the machine has alarge temperature difference, which quickly condenseswater droplets and slides into the drain box throughthe two fins to reduce the air humidity and achievethe effect of dehumidifcation.
ceiling mounted dehumidifier working principle
Working Principle 2

Installation

The dehumidifier should be installed in a place with air circulation, and avoid placing it in dead corners, causing short circuits in the air flow and failing to achieve the required dehumidification effect. At the same time, the dehumidifier should be placed on a firm and flat floor to avoid vibration and noise. Also, avoid direct sunlight or close to heating appliances.

ceiling mounted dehumidifier
ceiling mounted dehumidifier
Scroll to Top